Annual Sector Experience
Completed Large Project
MVA Transformer Substation Power
Occupational Health and Safety & Quality Standard
Integrated Engineering and Energy Solutions
Nur Energy is one of Turkey's leading solution partners in the field of high-voltage transmission lines, switchgear facilities, transformer substations, and industrial electromechanical contracting.
By integrating engineering disciplines under a single corporate umbrella, we operate with uncompromising quality, maximum occupational health and safety, and high productivity principles from planning to commissioning.
- Turnkey Switchgear & Transformer Substations
- High Voltage Transmission Lines
- Testing and Commissioning Services
- 24/7 Technical Service and Maintenance Guarantee
Our Areas of Activity & Engineering
We offer high-standard contracting services across a wide range of industrial facilities, urban infrastructure, and more.
Integrated Construction & Architecture
Collaboration with Phoenician Architecture for urban design, luxury residential construction, and aesthetic superstructure projects....
Service DetailsElectromechanical Contracting
Comprehensive electrical and mechanical infrastructure installations for hospitals, public buildings, and industrial facilities....
Service DetailsHigh Voltage & Power Lines
Turnkey installation of 380kV/154kV ENH facilities, transformer stations, and main energy distribution networks....
Service DetailsLandscape & Environmental Design
Collaboration with Phoenician Landscape for aesthetic and environmentally friendly landscape designs and green area layouts....
Service DetailsSolar Energy (GES) Systems
Solar power plant installations, material sales, and sustainable renewable energy infrastructure solutions....
Service DetailsLow Voltage & Security
Design and installation of CCTV, fire detection, and fiber optic communication systems for smart buildings....
Service DetailsUncompromising Engineering Standards
We work with international quality and safety standards that leave no room for error in the energy infrastructure.
TEİAŞ & TEDAŞ Onaylı Taahhüt
154kV / 380kV şalt tesisleri, trafo merkezleri ve enerji iletim hatlarında resmi şartnamelere %100 uyumlu anahtar teslim kurulum.
Torbalı Depoda Hazır Trafo Stoku
Sanayi tesisleri ve GES yatırımları için termin süresini sıfırlayan, test raporlu 160 kVA - 2500 kVA hazır transformatör envanteri.
Akredite DGA Yağ & İzolasyon Testi
IEC standartlarında dielektrik delinme, sargı direnci ve çözünmüş gaz analizi (DGA) ile kanıtlı laboratuvar test raporlaması.
7/24 Mobil YG Acil Müdahale
Organize sanayi bölgeleri ve endüstriyel tesislere tam donanımlı mobil test araçlarımız ve nöbetçi mühendislerimizle hızlı servis.
Our Official Quality Certificates and Standards
We provide engineering services at high standards with our official accreditation certificates approved by international ISO, TSE, TMMOB EMO and TEDAŞ.
ISO 9001:2015 Kalite Yönetim Sistemi Sertifikası
ISO 14001:2015 Çevre Yönetim Sistemi Sertifikası
ISO 45001:2018 İş Sağlığı ve Güvenliği Yönetim Sistemi
ISO 50001:2018 Enerji Yönetim Sistemi Sertifikası
ISO/IEC 27001:2022 Bilgi Güvenliği Yönetim Sistemi
TMMOB EMO Serbest Müşavir Mühendislik (SMM) Büro Tescil Belgesi
Large Projects Bearing Our Signature
Highlights of our successfully completed projects from healthcare campuses to energy transmission lines.
Stock Delivered 2nd Hand & Zero Power Equipment
Revisioned, oil and dielectric test report-based distribution transformers, cabin generators and industrial UPS systems for factories and construction sites.
Sıfır Ekipman BKS-1600-M Monoblock Compact Concrete Transformer Enclosure (1600 kVA)
Prefabricated reinforced concrete kiosk substation designed for housing distribution ...
Sıfır Ekipman SHL-SCH-SM6 Schneider Electric SM6 36 kV Modular MV Switchgear Cubicle
Air-insulated and SF6 gas disconnect modular medium voltage switchgear for transforme...
Sıfır Ekipman UPS-INF-200 Inform 200 kVA Modular Hot-Swappable Industrial UPS System
Scalable modular power protection with N+1 redundancy and hot-swappable power modules...
Sıfır Ekipman UPS-MAK-120 Makelsan 120 kVA 3-Phase Online Industrial UPS
Double-conversion online uninterruptible power supply for server rooms, medical equip...
Our Expert Engineering Team
We are at your service with our experienced engineers and site managers from high-voltage transformer centers to energy transmission lines.
Ferhat Tutka
Kurucu & Genel Müdür / Elektrik Kontrol Müdürü
Hakan Yazgan
Elektrik Proje Koordinatörü
Sadık Önder
İş Sağlığı ve Güvenliği (İSG) Başuzmanı
Hulusi Furkan Yazgan
Maliyet Kontrol ve Keşif Mühendisi
Sector Developments & Announcements
The latest news and technical articles in the energy and electromechanical world.
Harmonic Distortions in Industrial Facilities and Impacts on Transformer Efficiency
How variable frequency drives (VFDs) and non-linear industrial loads cause transformer overheating and eddy current losses; mitiga...
Read the News
Substation Safety Standards: OHS & Switching Procedures in 154 kV & 380 kV Yards
Life-critical occupational health and safety (OHS) protocols, mechanical interlocking, and step-by-step switching procedures in ex...
Read the News
Compact Monoblock Concrete Substations: Fast Installation & Type-Test Certified
Advantages of prefabricated, type-tested monoblock concrete compact substations that drastically reduce on-site civil works....
Read the NewsFrequently Asked Technical Questions
Our engineers have answered the most critical questions about high-voltage operation responsibility, transformer tests, compensation, and GES regulations.
Why is DGA (Dissolved Gas Analysis) testing critical for transformer oil?
DGA (Dissolved Gas Analysis) detects electrical and thermal faults within the transformer's internal structure (arcing, partial discharge, overheating) well before equipment failure occurs. Concentrations of key gases dissolved in insulating oil—such as hydrogen (H2), methane (CH4), ethylene (C2H4), and acetylene (C2H2)—are analyzed in compliance with IEC 60599 and IEEE C57.104 standards to preemptively mitigate explosion or fire hazards.
What are the standard dielectric breakdown voltage limits for transformer insulating oil?
According to IEC 60156 standards, the breakdown voltage of insulating oil in operational transformers must be at least 30 kV / 2.5 mm across standard test electrodes. For newly filled or reclaimed oils, values exceeding 60-70 kV are expected. Insulating oil dropping below 30 kV must immediately undergo vacuum purification (degassing and dehydration).
What is a Buchholz Relay and under what conditions does it de-energize the transformer?
A Buchholz relay is a mechanical and hydraulic protective device installed in the pipe between the oil conservator tank and the main transformer tank. When minor gas generation occurs due to winding short circuits or insulation degradation, the relay's upper float triggers an alarm. In the event of a sudden and violent oil surge caused by severe internal faults, the lower flap trips the high-voltage circuit breaker within milliseconds, protecting the transformer.
What protocol is followed if the SF6 gas pressure drops in high-voltage circuit breakers?
SF6 (Sulfur Hexafluoride) gas provides superior arc quenching and dielectric insulation. When the pressure gauge reaches the alarm threshold (typically 0.55 MPa), immediate leak detection and sealing inspections are conducted. If the pressure falls to the lockout level, breaker operation is automatically inhibited. At this stage, the system is controlled and de-energized to execute gas replenishment and gasket refurbishment.
Smart Project and Site Survey Wizard
Choose the engineering field you need, specify the technical details; our expert team will provide a feasibility and approximate cost report within 24 hours.